Horoscope

Saturday, 26 April 2014

BT-VS Class B Pulsating Vacuum 2 door pressure sterilizer autoclave

BT-VS Class B Pulsating Vacuum 2 door pressure sterilizer autoclave

 Detail

Type: Pressure Steam Sterilization  Equipments   Brand Name:
Bestran pressure sterilizer autoclave 
Model Number:        
pressure sterilizer autoclave BT-VS
Place of Origin: Jiangsu China                         (Mainland) Certificates:
ISO13485,CE pressure sterilizer                     autoclave
Design pressure:
0.245Mpa pressure sterilizer autoclave
Design Max. temperature:
139℃ pressure sterilizer autoclave
Working pressure: 0.22Mpa Working Max. temperature: 134℃
Heat Equilibrium: ≤±1℃ Vacuum: ~0.09Mpa  Steam source pressure: 0.3-0.5Mpa
Steam consumption: 40kg/cycle Cooling Water source pressure: 0.2-0.3Mpa






Specifications

pressure sterilizer autoclave
1.CE
2 touch screen operation
3 printing system
4 high precision pressure controller

Class B 60L-5000L Touch-screen operation with printing sytem Pulsating Vacuum pressure sterilizer autoclave
Model:  BT-VS
BT-VS Class B Pulsating Vacuum 2 door pressure sterilizer autoclave



Product Description
  
1.General
Pulsating vacuum sterilizer is strictly designed and manufactured in accord with GMP technical Standard. It has passed ISO9001 quality management qualification standard and ISO13485:2003 Certificate of Quality Management System for Medical Devices.
The relevant data can be saved and printed automatically.
This autoclave is suitable for pharmaceutical factory, hospital, scientific research institute and other units to sterilize and dry asepsis clothes, instruments, culture medium, etc.
2.Size & Utilities
Design Pressure0.245MpaVacuum-0.095Mpa
Working Pressure0.22MpaCity Water supply pressure0.2-0.3Mpa
Design Temperature139°CCompressed Air supply pressure0.6-0.8Mpa
Working Temperature134°CSteam pressure0.4-0.6Mpa
Heat equilibrium≤±1°C

ModelOverall Size
D*W*H(mm)
Chamber Size D*W*H(mm)Steam (kg/cycle)Compressed
Air (m³/cycle)
City water (kg/cycle)Power
(Kw)
N.W
(kg)
BT-VS0.1825*1080*1600630*400*480150.1801.0380
BT- VS0.15995*1080*1600800*400*480180.1901.0420
BT- VS0.25895*1220*1720700*600*600200.11501.5650
BT- VS0.361195*1220*17201000*600*600250.11501.5760
BT- VS0.41295*1220*17201100*600*600280.11801.5800
BT- VS0.61245*1300*18801050*680*850300.12002.01100
BT- VS0.81595*1300*18801400*680*850350.12503.01300
BT- VS1.21695*1370*19601500*750*1100400.13003.01900
BT- VS2.53195*1370*19603000*750*1100750.14504.52800
BT- VS5.03635*1800*22003400*1000*15001500.16007.54500


3.Structure and performance features
(1)      Chamber material: the chamber adopts the SUS316L, According to mechanical and chemical treatment, the chamber surface is bright, beautiful and corrosion resistant.
(2)      The insulating layer is made by aluminium silicate which is the best insulating material, and the equipment is rectangular, having stainless steel decorating cover
(3)      Doors: The autoclave adopt double door ( Pneumatic locking, opened hinged door by manual). Both doors cannot be opened simultaneously.
  • Ø         The door seal is the inflatable type, pressurized with compressed air, and can withstand the chamber temperature and pressure.
  • Ø         The doors shall have a safety mechanism to prevent opening of the door when the chamber is hot or pressurized or when the autoclave is in operation.
  • Ø         Sterilization cycle can start only after the door is fully closed and locked.
(4)      Pipeline system is consisted of vacuum pump, pneumatic valve,air filter,etc.
  • Ø         Angle type of pneumatic valve: strong switch valve, without any mistake, remote compressed gas control. with the inner chamber of interlinked valve for stainless steel clamp type seat.
  • Ø         Vacuum pump:The autoclave include a liquid ring vacuum pump to obtain vacuum in the chamber.
  • Ø         The filters for air filling pipe is from PALL company. The performance is excellent with no medium break or contamination unload. That can be repeated clean and repeated flush.
(5)      Control system: PLC+ HMI + Micro-printer. a timely data printing, should be able to default one or more sterilization cycle.Electric apparatus system adopts domestic or imported components whose performance is stable and reliable.
  • Ø         When automatic controller in the failure of the circumstances, the security device makes the sterilization indoor pressure safety in the pressure of the atmosphere to the back of the state, and allow the loading door can be opened.
  • Ø         In order to maintenance, test and emergency needs, manual operation can be through the use of access control tools to complete.
  • Ø         The master controller system: can set the user name and password, also can set up different user access. A manager, users, maintainers triple interface function. Managers can be used according to different level, set on use of a password, ensure use safety, prevent that due to improper operation or modify the program brings experiment. 
  • Ø         Touch screen: display work process parameters, control is simple, the operation is convenient. Interface has the following functions:
Display shows the process of sterilization cycle state, time,pressure,temperature,two-door airtight state, the running records, printing, etc.
(6)      The system have an E-Stop mechanism designed to stop all physical movement of the equipment immediately.
(7)      The GMP confirming connecter fixed can provide the GMP validation for the customer freely.